Online Troubleshooting Guide

To help our Semi-Group/IPE/PME/1700 users, we provide an online trouble-shooting guide to let you diagnose most common problems your system.


Directions: Read the items in the following list. The list is presented in a top down order. Start your troubleshooting at the first item and go to the last. The goal is to verify that the system hardware is OK by running the standard test plasma. At each new question, click on the link to help you isolate the trouble to a particular module:

Trouble-shooting flow diagram


Main Power or electrical

Check the following items in this order:

  1. Facilities AC at power panel
  2. EMO circuit (24VAC, key lock switch, reset button)
  3. Circuit Breakers (on power distribution & back of some modules)
  4. Fuses (on hoist controller & back of some modules)
  5. Door & panel switches
  6. Interlocks (AC, panels, Atm/Vac)

If POWER problem still exists, please try the following:


Chamber Hoist

If the process chamber will not go up, check the following:

  1. Is chamber vented (is there a small gap at the base plate)?
  2. Is the vent N2 pressure OK?
  3. Is atmosphere switch true?
  4. Are the hoist chain and gears OK?
  5. Check hoist relays and front panel switches
  6. Is the hoist motor plugged in?
  7. Is the hoist 110Vac power on?
  8. Is the system controller (24Vdc) power on?
  9. Check hoist limit switches
  10. Check hoist power supply rectifier

If HOIST problem still exists, please try the following:


Vacuum subsystems

If the system will not pump down to 150mT, check the following:

  1. Pumps OK?
  2. Are the system and exhaust valve controllers on (+/-15Vdc)?
  3. Manometer OK?
  4. Is chamber down (is there a gap at the base plate)?
  5. Valves OK?
  6. Leak check system
  7. Check for leaks across isolation valve seats (gases/N2)
  8. Does the pressure go down when you turn off the H20?

If VACUUM problem still exists, please try the following:


Gas subsystems

If the gas flow or pressure is not stable, check the following:

  1. Compressed air set to 80 psi?
  2. Regulators set to 15psi? (less for liquid sources: SiCl4,SF6,BCl3)
  3. Gas Sources OK & not empty?
  4. Isolation, Manometer, Throttle Valves working?
  5. Are exhaust valve controller settings normal?
  6. MFC's (zero, stability, control) See also: MFC trouble guide

If GAS problem still exists, please try the following:


RF sources

Run Standard test plasma and check the following:

  1. RF Power Supply settings normal (in auto, remotes on, etc.)
  2. Interlocks OK? (Doors, Vacuum Switch, Temp, etc.)
  3. Tuner settings normal (in auto, remotes on, etc.)
  4. Debris shorting electrode to dark space shield?
  5. RF & electrical connections OK?
  6. Electrical or RF Shorts around Tuner or Electrode?
  7. Cooling Water flow OK & impedance >500k ohm
  8. Electrodes coated, dirty, or damaged?

If RF problem still exists, please try the following:


System Controller

If the process is not running or ending correctly, check the following:

  1. Verify that stored recipe parameter values are as expected
  2. Check Endpoint detector operation or settings
  3. Review historical data and run process calibration tests
  4. Inspect Substrate batches for dissimilarities
  5. Inspect for Contamination (internal & external)
  6. Review Operating procedures

If CONTROL problem still exists, process or substrate adjustments are required. Also, please try the following:


Process Questions

If the process is not running or ending correctly, check the following:

  1. No online help is available for this topic yet
  2. Request assistance from the AGS Support desk

If PROCESS is still not acceptable, please try the following:


Miscellaneous Questions
  1. No online help is available for this topic yet
  2. Request assistance from the AGS Support desk

Standard Test Recipes


Use these "standard" recipes for test plasma (optimized for 50mm gap setting):

Return to Index or Continue to check RF Systems


Have a question or your own idea for a improving the diagram?
Let us know at the AGS Support desk