To help our Semi-Group/IPE/PME/1700 users, we provide an online
trouble-shooting guide to let you diagnose most common problems your system.
Directions: Read the items in the following list. The list
is presented in a top down order. Start your troubleshooting at the first item
and go to the last. The goal is to verify that the system hardware is OK by
running the standard test plasma. At each new
question, click on the link to help you isolate the trouble to a particular
module:
Trouble-shooting flow diagram
Main Power or electrical
Check the following items in this
order:
- Facilities AC at power panel
- EMO circuit (24VAC, key lock
switch, reset button)
- Circuit Breakers (on power
distribution & back of some modules)
- Fuses (on hoist controller
& back of some modules)
- Door & panel switches
- Interlocks (AC, panels,
Atm/Vac)
If POWER problem still exists, please try the following:
If the process chamber will not go
up, check the following:
- Is chamber vented (is there
a small gap at the base plate)?
- Is the vent N2 pressure OK?
- Is atmosphere switch true?
- Are the hoist chain and
gears OK?
- Check hoist relays and front
panel switches
- Is the hoist motor plugged
in?
- Is the hoist 110Vac power
on?
- Is the system controller
(24Vdc) power on?
- Check hoist limit switches
- Check hoist power supply rectifier
If HOIST problem still exists, please try the following:
If the system will not pump down to
150mT, check the following:
- Pumps OK?
- Are the system and exhaust
valve controllers on (+/-15Vdc)?
- Manometer OK?
- Is chamber down (is there a
gap at the base plate)?
- Valves OK?
- Leak check system
- Check for leaks across
isolation valve seats (gases/N2)
- Does the pressure go down
when you turn off the H20?
If VACUUM problem still exists, please try the following:
If the gas flow or pressure is not stable,
check the following:
- Compressed air set to 80 psi?
- Regulators set to 15psi?
(less for liquid sources: SiCl4,SF6,BCl3)
- Gas Sources OK & not
empty?
- Isolation, Manometer,
Throttle Valves working?
- Are exhaust valve controller
settings normal?
- MFC's (zero, stability,
control) See also: MFC trouble guide
If GAS problem still exists, please try the following:
Run Standard
test plasma and check the following:
- RF Power Supply settings normal
(in auto, remotes on, etc.)
- Interlocks OK? (Doors,
Vacuum Switch, Temp, etc.)
- Tuner settings normal (in
auto, remotes on, etc.)
- Debris shorting electrode
to dark space shield?
- RF & electrical
connections OK?
- Electrical or RF Shorts around
Tuner or Electrode?
- Cooling Water flow OK &
impedance >500k ohm
- Electrodes coated, dirty,
or damaged?
If RF problem still exists, please try the following:
If the process is not running or
ending correctly, check the following:
- Verify that stored recipe
parameter values are as expected
- Check Endpoint detector
operation or settings
- Review historical data and
run process calibration tests
- Inspect Substrate batches
for dissimilarities
- Inspect for Contamination
(internal & external)
- Review Operating procedures
If CONTROL problem still exists, process or substrate
adjustments are required. Also, please try the following:
If the process is not running or
ending correctly, check the following:
- No online help is available
for this topic yet
- Request assistance from the
AGS Support desk
If PROCESS is still not acceptable, please try the
following:
- No online help is available
for this topic yet
- Request assistance from the AGS Support desk
Use these "standard" recipes for test plasma (optimized for 50mm gap
setting):
- RIE (with RF,
13.56mHz power supply)
- ROUGH=150mT, VENT=0.1sec,
TEMP=0 degrees
- THROT= 100mT
- GASx = 50 sccm (use
O2 or N2 if available)
- RF = 300 watts
- Result should be a stable,
uniform plasma, with 500+/-50 Vdc bias (in O2) and reflected power below
5% if all subsystem are OK.
- PECVD (with RF,
13.56mHz power supply)
- ROUGH=150mT,
VENT=0.1sec, TEMP=100 degrees
- THROT= 300mT
- GASx = 50 sccm (use
N2 or O2 if available)
- RF = 60 watts
- Result should be a stable,
uniform plasma, and reflected power below 5% and temperature +/-5deg if
all subsystem are OK
Return to Index or Continue to check RF Systems
Have a question or your own idea for
a improving the diagram?
Let us know at the AGS Support desk